FrançaisABSTRACT
Dental implants are a modern therapeutic solution proposed for the partial or total replacement of teeth. Since the 1980s the foremost material for this dental application has been titanium and its alloys. The success of an implant is adequate osseointegration in the jaw. This requires the use of coatings and surface treatments for best and fastest healing. However, because of the buccal medium (saliva), and the masticatory function, implants have to withstand combined corrosion and mechanical wear (tribocorrosion). This article gives an overview of these different issues.
Read this article from a comprehensive knowledge base, updated and supplemented with articles reviewed by scientific committees.
Read the articleAUTHOR
-
Caroline RICHARD: Doctorate in mechanics, materials and acoustics - University Professor, François Rabelais University, Tours, France
INTRODUCTION
The replacement of a natural tooth, in order to meet the numerous biological, mechanical, functional and aesthetic constraints, requires a complex structure, comprising several superimposed elements and using certain materials and surface treatments. An implant replaces a defective tooth root with a device, usually metal, screwed into the bone. It's an artificial root inserted into the jawbone to create a strong, durable anchorage. A dental implant is then used to place a superstructure (abutment) on which an esthetic crown or a dental prosthesis (made up of several crowns) is placed, known as an "implant-supported" prosthesis. It can be likened to a screw of variable length, width and shape (one of the smallest implants on the market is around 4 mm in length and 4 mm in diameter). It transfers masticatory forces to the bone in which it is anchored. The ideal implant should not alter over time as it comes into contact with gingiva, saliva and other elements of the oral cavity. Today, almost 99% of dental implants are made of titanium or titanium alloy. In dentistry, titanium offers a number of advantages over other metals, thanks in particular to its physical and chemical properties, which have enabled it to establish itself in the technical and therapeutic arsenal. In addition to its well-known high mechanical strength and low density, which have led to its widespread use in a wide range of industrial sectors, it is its incredible biocompatibility that has come to the fore in the medical sector, largely due to the formation of a passive protective film on its surface when exposed to an aggressive environment. Every year, 11 million crowns and bridges are fitted in France. Prostheses require considerable investment (operating theatres, sterilization and traceability chains, specific room layouts, etc.). This article shows different aspects of the state of the art of modern dental implantology in terms of durability, corrosion and surface treatments used.
As is customary in the industry, unless otherwise specified, the percentages given are by mass.
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference
KEYWORDS
titanium | | acidic etching | sandblasting | coating
This article is included in
Healthcare technologies
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Dental implants: corrosion and surface treatments
Bibliography
Events
Société française du vide SFV Paris France https://www.vide.org
Annual membership days JADH organized by SFV
Bi-annual conferences, European Conference on Applications of Surface and Interface Analysis, ECASIA, some conferences are published in the journal Surface and Interface analysis
Standards and norms
- Oral medicine – Medical devices for oral medicine – Dental implants - NF EN 1642 - 06-13
- Biological evaluation of medical devices – Part 1: Assessment and testing as part of a risk management process - NF EN ISO 10993-1 - 07-10
- Surgical implants – Hydroxyapatite – Part 6: Powders - ISO 13779-6 - 2015
- Medical devices – Quality management systems – Requirements for regulatory purposes - ISO 13485...
Regulations
Articles R. 5212-36 to R. 5212-42 of the Public Health Code concerning traceability
Article L. 5211-3 of the French Public Health Code concerning the creation of a patient file "traceability of orthodontic prostheses and/or appliances".
Article R. 5211-39 of the French Public Health Code concerning the conformity of medical devices.
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Straumann France http://www.straumann.fr
Global D http://www.globald.com
Zimmer Dental SAS http://www.zimmerdental.fr/fr/
...Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference