4. Tribocorrosion of dental implants
Tribocorrosion, which is caused by the dual action of wear and corrosion, can occur under a variety of conditions (sliding, wear due to small deflections, rolling, impact) in a corrosive environment.
4.1 Tribocorrosion under sliding conditions
Tribocorrosion studies on titanium, its untreated alloys and alloys with treated surfaces under sliding conditions are shown in Tables 1 and 2 . In general, tribocorrosion work is focused on the evaluation of surface treatments (table 3 ), which improve the wear and corrosion performance of materials (Ti6Al4V or Cp-Ti), and on the analysis...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference
This article is included in
Healthcare technologies
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Tribocorrosion of dental implants
Bibliography
Events
Société française du vide SFV Paris France https://www.vide.org
Annual membership days JADH organized by SFV
Bi-annual conferences, European Conference on Applications of Surface and Interface Analysis, ECASIA, some conferences are published in the journal Surface and Interface analysis
Standards and norms
- Oral medicine – Medical devices for oral medicine – Dental implants - NF EN 1642 - 06-13
- Biological evaluation of medical devices – Part 1: Assessment and testing as part of a risk management process - NF EN ISO 10993-1 - 07-10
- Surgical implants – Hydroxyapatite – Part 6: Powders - ISO 13779-6 - 2015
- Medical devices – Quality management systems – Requirements for regulatory purposes - ISO 13485...
Regulations
Articles R. 5212-36 to R. 5212-42 of the Public Health Code concerning traceability
Article L. 5211-3 of the French Public Health Code concerning the creation of a patient file "traceability of orthodontic prostheses and/or appliances".
Article R. 5211-39 of the French Public Health Code concerning the conformity of medical devices.
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Straumann France http://www.straumann.fr
Global D http://www.globald.com
Zimmer Dental SAS http://www.zimmerdental.fr/fr/
...Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference