1. Location and environment
1.1 Access roads for fire-fighting vehicles (article GH 6)
1. Building exits on levels accessible to public fire-fighting and rescue service equipment may not be more than 30 m from a road open to traffic at both ends and allowing the movement and parking of such equipment.
2. On these roads, a pathway meeting the following minimum requirements is permanently reserved for firefighters:
clear height of 3.50 m ;
roadway width, excluding parking lanes, of 3.50 m ;
load-bearing capacity of 160 kN calculated for one vehicle with a maximum of 90 kN per axle, the axles being at least 3.60 m apart;
punching resistance...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference
This article is included in
Preparing for construction
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Location and environment
Bibliography
Also in our database
Websites
Efectis France
Standards and norms
- Fire resistance testing of technical installations – Part 3: Hopper seals - NF EN 1366-3 - 11-12
- Building work – Suspended ceilings – Part 1-1: Cahier des clauses techniques types (CCT) Classification number : P68-203-1-1 - NF DTU 58.1 P1-1 - 12-08
- Fire classification of building products and components – Part 2: Classification based on fire resistance test data excluding products used in ventilation systems...
Code
Articles L. 111-8 – Code de la construction et de l'habitation – Persons with disabilities or reduced mobility.
Article L. 122-1 – Code de la construction et de l'habitation – Chapter II: Safety provisions for high-rise buildings.
Article R. 122-2 of the French Construction and Housing Code, amended by Decree no. 2009-1119 of September 16, 2009.
Article R....
Regulations
Décret n° 88-1056 du 14 novembre 1988 pris pour l'exécution des dispositions du livre II du Code du travail (titre III : Hygiène, sécurité et conditions du travail) en ce qui concerne la protection des travailleurs dans les établissements qui mettent en œuvre des courants électriques (NOR : TEFT8804060D).
Décret n° 2000-810 du 24 août 2000 relatif à la mise sur le marché des ascenseurs (NOR : EQUX0000110D)....
Directory
Organization
CECMI – Comité d'étude et de classification des matériaux et éléments de construction par rapport au danger d'incendie (Committee for the study and classification of building materials and elements with respect to fire hazard)