Article | REF: CHV2225 V1

Labs on a Chip for Chemistry. Principles and Characteristics

Authors: Clarisse MARIET, Christine DALMAZZONE, Marie MARSIGLIA, Laurent VIO, Axel VANSTEENE, Emmanuel MIGNARD

Publication date: June 10, 2019

You do not have access to this resource.
Click here to request your free trial access!

Already subscribed? Log in!


Overview

Français

ABSTRACT

The evolution of labs-on-chips are pushing the limits of miniaturization by integrating all stages of analysis, since the preparation of the samples up to the analysis of the results. First used in the field of biology in the form of biochips, are now essential tools for chemists from all areas. This article first recalls the highlights of microfluidics, then presents the specificities of microfluidics for applications to radiochemical separations and chemical and physicochemical characterizations for fine chemicals.

Read this article from a comprehensive knowledge base, updated and supplemented with articles reviewed by scientific committees.

Read the article

AUTHORS

  • Clarisse MARIET: Research engineer - Direction de l'Énergie Nucléaire (DEN), Service d'Études Analytiques et de Réactivité des Surfaces (SEARS), CEA, Université Paris-Saclay, Gif sur Yvette, France

  • Christine DALMAZZONE: Research engineer - Applied Physics, Chemistry and Mechanics Department - IFP Énergies nouvelles (IFPEN), Rueil-Malmaison, France

  • Marie MARSIGLIA: Research engineer - Applied Physics, Chemistry and Mechanics Department - IFP Énergies nouvelles (IFPEN), Rueil-Malmaison, France

  • Laurent VIO: Research engineer - Direction de l'Énergie Nucléaire (DEN), Service d'Études Analytiques et de Réactivité des Surfaces (SEARS), CEA, Université Paris-Saclay, Gif sur Yvette, France

  • Axel VANSTEENE: Doctoral student - Direction de l'Énergie Nucléaire (DEN), Service d'Études Analytiques et de Réactivité des Surfaces (SEARS), CEA, Université Paris-Saclay, Gif sur Yvette, France

  • Emmanuel MIGNARD: Research Manager - CNRS, University of Bordeaux, Solvay, LOF, UMR 5258, Pessac, France

 INTRODUCTION

The concept of labs-on-a-chip dates back to the early 1990s, but developments have been teeming and shaking up the biotech sector since the 2000s, as evidenced by the evolution in the number of articles whose subject contains the keyword "microfluidics", which refers to both the science and design of labs-on-a-chip and at least one of whose characteristic dimensions is of the order of a few tens of micrometers, in the Thomson ISI Web of Knowledge database. This number of articles has risen from 28 in 1998 to over 2,200 in 2017 alone (survey conducted in July 2018). Since then, labs-on-a-chip have become ubiquitous in many fields: in medicine, energy, green chemistry, cosmetics, the food industry..., but what are the real benefits of this technology for chemistry? What are their specific features? How are they developed?

Microfluidics has attracted the interest of the chemical industry, motivated largely by applications in analysis, synthesis and process intensification. For example, such downscaling is relevant in the nuclear field, or for industries manufacturing toxic or explosive products, as it would enable :

  • Reduce waste production (reagents, laboratory consumables, decontamination solution, etc.);

  • automate unit operations in chemical processes;

  • reduce radiological and chemical exposure of personnel ;

  • reduce costs (e.g. by transferring analyses from shielded enclosures to glove boxes).

Mainly used in the physico-chemistry of complex fluids on systems operating in near-ambient conditions, microfluidics is also of interest for conducting experiments under more severe conditions (high pressure, high temperature), representative of the industrial operating conditions encountered in various applications, ranging from oil exploration/production, through refining and petrochemicals, to biomass processing, biofuel synthesis...

This paradigm shift in organic chemistry is helping to improve :

  • productivity ;

  • selectivity. For reactions carried out in a two-phase medium, the absence of mixing is exploited at the end of the reaction: the product extraction and purification stage is eliminated, and the products are located exclusively in one of the two phases.

  • thermal control linked to the surface/volume ratio and the possibility of positioning sensors as close as possible to the reaction;

  • risk management.

High-throughput screening of operating conditions is also of interest to chemists in all fields. This...

You do not have access to this resource.

Exclusive to subscribers. 97% yet to be discovered!

You do not have access to this resource.
Click here to request your free trial access!

Already subscribed? Log in!


The Ultimate Scientific and Technical Reference

A Comprehensive Knowledge Base, with over 1,200 authors and 100 scientific advisors
+ More than 10,000 articles and 1,000 how-to sheets, over 800 new or updated articles every year
From design to prototyping, right through to industrialization, the reference for securing the development of your industrial projects

KEYWORDS

microfluidics   |   Enhanced Oil Recovery   |   radionuclides   |   elementary separation


This article is included in

Unit operations. Chemical reaction engineering

This offer includes:

Knowledge Base

Updated and enriched with articles validated by our scientific committees

Services

A set of exclusive tools to complement the resources

Practical Path

Operational and didactic, to guarantee the acquisition of transversal skills

Doc & Quiz

Interactive articles with quizzes, for constructive reading

Subscribe now!

Ongoing reading
Chemistry laboratories-on-a-chip