3. Some minimum performance values for buildings
3.1 Main sound insulation values between premises in a building (residential or commercial)
If we consider all the decrees relating to noise limitation in various buildings, the standardized acoustic insulation required ranges from 25 to 60 dB (or even 82 dB in the case of a shared room between a hall where amplified music is produced and a dwelling or hotel room).
Isolations between 25 and 40 dB all correspond to cases where there is a door in the separating wall between the rooms to be insulated.
-
The 25 dB insulation level is reserved for nursery schools, where communication doors are fitted with "anti-pinch" devices that do not provide a sufficient seal between the door and its frame.
...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference
This article is included in
Environment
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Some minimum performance values for buildings
Standards and norms
- Laboratory measurement of sound insulation of building components – Part 2: Measurement of airborne sound insulation. - NF EN ISO 10140-2 - 2021
- Laboratory measurement of sound insulation of building components – Part 3: Measurement of impact sound insulation. - NF EN ISO 10140-3 - 2021
- Assessing the sound insulation of buildings and building components – Part 1: Airborne sound insulation - NF EN ISO 717-1...
Regulations
(list in chronological order of texts in force in May 2021)
Loi n° 92-1444 du 31 décembre 1992 relative à la lutte contre le bruit – J.O. du 1 er janvier 1993 – NOR : ENVX9200186L.
Arrêté du 30/08/1990 pris pour l'application de l'article R, 235-11 du code du travail et relatif à la correction acoustique des locaux de travail –...
Appendice
Table 1 lists the standardized sound insulation values to be found in the decrees relating to the acoustic characteristics of buildings: a decree dated June 30, 1999 (residential buildings) and the three decrees dated April 25, 2003 (educational establishments; health establishments; hotels). The full text of these decrees is available at http://www.legifrance.gouv.fr/Les. The first two lines correspond to the main reception...
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Software tools
AcouBAT by CYPE: building acoustic performance simulation software. It also contains an extensive database of product performance data.
Documentation – Training – Seminars (non-exhaustive list)...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference