Overview
FrançaisABSTRACT
Bone remodeling depends largely on the mechanical properties of the implant. This article aims to present the interest of titanium alloys with low elastic modulus for medical applications such as implants and prostheses. In chapter 1 are recalled briefly the biochemical and mechanical aspects at the bone/implant interface. Chapter 2 provides the chronological evolution of the development of titanium alloys for medical applications. Chapter 3 describes the various formulation approaches leading to obtain new titanium alloys with low elastic modulus. The mechanical behavior of titanium alloys is presented in the 4th chapter. The optimization strategies are presented in the 5th chapter. The last chapter illustrates the effects of the elastic modulus of a dental implant on the stress distribution in the peri-implanted bone.
Read this article from a comprehensive knowledge base, updated and supplemented with articles reviewed by scientific committees.
Read the articleAUTHORS
-
Pascal LAHEURTE: Senior Lecturer - Laboratory for the study of microstructures and mechanics of materials - University of Lorraine, France
-
Wafa ELMAY: Doctorate in materials engineering - Arts et métiers Paris Tech, Metz, France
-
Frédéric PRIMA: Structural Metallurgy Team - Institut de Recherche de Chimie Paris (UMR 8247), ParisTech, France
-
Thierry GLORIANT: Chemistry and Metallurgy Laboratory, INSA, Rennes, France
INTRODUCTION
Interest in titanium alloys used in the medical field for bone replacement and reconstruction has grown considerably in recent decades. Their fields of application are vast: maxillofacial surgery, ENT, orthopedics, implantology... These alloys represent a considerable economic and social challenge. As life expectancy rises, these materials have to meet increasingly demanding specifications in terms of both chemical and mechanical biocompatibility, in order to last in the human body. The success of the operation depends to a large extent on the complex osseointegration mechanisms involving both mechanical and biochemical aspects occurring at the implant/surrounding tissue interface.
Mechanical osseointegration, which conditions a large part of bone remodeling (i.e. the healing response of the bone), has long been ignored in the selection of biomaterials for prostheses and implants. For a long time, the criteria sought were essentially limited to good corrosion resistance, high mechanical strength and ductility to facilitate shaping. However, the presence of an implant in the bone leads to a redistribution of mechanical stresses (a phenomenon known as "stress-shielding"). Too great a difference in rigidity between bone and implant leads to stress concentration zones and unloaded zones, resulting in necrosis or osteolysis and compromising the implant's durability. The mechanical properties of implants/prostheses, and in particular the modulus of elasticity, must therefore be carefully adapted, as they determine the quality of stress transfer at the implant/bone interface.
Pure titanium and the TA6V alloy offer the best compromise in terms of combination of properties, in particular because of their elastic modulus (E = 100 GPa) (half that of steels), high strength in the 900 to 1,000 MPa range and recognized biocompatibility in the case of titanium. However, the modulus of elasticity of these alloys is not perfectly matched to that of cortical bone, which is estimated at 20 to 30 GPa. What's more, the presence of elements such as vanadium and aluminum entails toxicity risks, which health professionals cite as one of the causes of implant failure.
Research has therefore recently focused on the development of new titanium alloys, with biomimicry taking into account the adaptation of implant mechanical properties to the bone matrix. Titanium alloys, containing only non-toxic elements, represent an excellent alternative to the materials mentioned above. In particular, β-metastable titanium alloys are of great interest for biomedical applications. Due to their metallurgical characteristics, these alloys have a very wide range of properties that can be modulated by heat and/or mechanical treatments, in order to obtain a better compromise between...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference
KEYWORDS
mechanical biocompatibility | metastable phases | martensitic transformation | implantology | prosthesis
This article is included in
Eco-design and sustainable innovation
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Titanium and alloys
Bibliography
Patents
Process for the thermomechanical treatment of a titanium alloy, alloy and prosthesis thus obtained. Inventors: LAHEURTE (P.), PRIMA (F.), GLORIANT (T.), ELMAY (W.), EBERHARDT (A.), PATOOR (E.); March 16, 2013, Patent WO 2013/068366 A1.
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference