
1. Data and working hypotheses
The pump selected is a type NM 252 from Ingersoll Dresser Pumps with the following characteristics:
maximum output flow: Q RM = 1,100m 3 /h ;
height of elevation: H RM = 59 m ;
maximum efficiency: η M = 85% ;
power consumption at maximum output: P RM = 208.5 kW.
The H(Q), P (Q), η(Q) curves for the NM 252 pump are shown on the graph in figure 1 .
In our application, we adopt...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!

The Ultimate Scientific and Technical Reference
This article is included in
Electricity networks and applications
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Data and working hypotheses
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!

The Ultimate Scientific and Technical Reference