9. Conduits and ducts
9.1 General provisions for shafts, hoppers, ducts and conduits
Appropriate measures must be taken to prevent the passage of smoke from the affected compartment to other parts of the building.
Stairwells, elevator shafts and freight elevator shafts are constructed of non-combustible or A1 materials, with a 2-hour fire-resistance rating, EI 120 or REI 120.
All other vertical ducts are placed in ducts, unless they themselves have a penetration fire-resistance rating equal to the fire-resistance rating of the wall they pass through.
SCROLL TO TOPExclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference
This article is included in
Preparing for construction
This offer includes:
Knowledge Base
Updated and enriched with articles validated by our scientific committees
Services
A set of exclusive tools to complement the resources
Practical Path
Operational and didactic, to guarantee the acquisition of transversal skills
Doc & Quiz
Interactive articles with quizzes, for constructive reading
Conduits and ducts
Bibliography
Also in our database
Code
Article R. 4512-7 du Code du travail créé par décret n° 2008-244 du 7 mars 2008 – art. (V).
Article R. 122-2 of the French Construction and Housing Code, amended by Decree no. 2009-1119 of September 16, 2009.
Regulations
Order of March 19, 1993 (in application of article R. 237-8 of the French Labor Code, this order establishes the list of hazardous jobs for which a written prevention plan is drawn up).
Arrêté du 3 octobre 2010 relatif au stockage en réservoirs aériens manufacturés de liquides inflammables exploités dans un stockage soumis à autorisation au titre de la rubrique 1432 de la législation des installations...
Standards and norms
- Fire detection equipment –Autonomous trigger detector systems (SDAD) - NF S61-961 - 09-07
- Safety rules for elevator construction and installation – Special applications for elevators and freight elevators – Part 72: fire elevators - NF EN 81-72 - 05-04
- Méthode d'essai pour l'exposition des toitures à un feu extérieur - ENV 1187 - 2002
- Fire classification of building products and components – Part...
Exclusive to subscribers. 97% yet to be discovered!
You do not have access to this resource.
Click here to request your free trial access!
Already subscribed? Log in!
The Ultimate Scientific and Technical Reference